Diff for "ResponseCollection" - Meg Wiki
location: Diff for "ResponseCollection"
Differences between revisions 3 and 5 (spanning 2 versions)
Revision 3 as of 2007-05-18 09:13:31
Size: 713
Comment:
Revision 5 as of 2007-05-18 09:18:21
Size: 958
Comment:
Deletions are marked like this. Additions are marked like this.
Line 7: Line 7:
boxes can be used with the table insert for the MEG seat. boxes can be used with the table insert for the MEG seat. They are a bit slippery and produce
an audible click when pressed, and it might be good to put them on a mouse mat for these
reasons (the mat prevents the table insert to resonate with the button click).
Line 9: Line 11:
[[ImageLink(buttonboxes.pgn, //MegCBU, height=450)]] [[ImageLink(buttonboxes.pgn, //MegCBU, height=600)]]
Line 12: Line 14:
but a strip of material that has to bu pushed down. The normal button boxes will click when
switching, but these EN panels don't. They also have a tendency to come on again if the
strip is pushed deeper, producing the sequence on-off-on-off-on for a single press.
but a strip of material that has to be pushed down. The normal button boxes will click when
switching, but these EN panels don't give any tactile feedback. They also have a tendency to
come on again if the strip is pushed deeper, producing the sequence on-off-on-off-on for
a single press and release.

Response collection

Button boxes

We have two 4-button optical button boxes for use with the MEG. Usually all 8 outputs will be connected to the trigger box in the stimulus cabinet. The channels used are 9-16. These boxes can be used with the table insert for the MEG seat. They are a bit slippery and produce an audible click when pressed, and it might be good to put them on a mouse mat for these reasons (the mat prevents the table insert to resonate with the button click).

ImageLink(buttonboxes.pgn, //MegCBU, height=600)

EN also supplied us with two button panels, which work in a different way. There's no button but a strip of material that has to be pushed down. The normal button boxes will click when switching, but these EN panels don't give any tactile feedback. They also have a tendency to come on again if the strip is pushed deeper, producing the sequence on-off-on-off-on for a single press and release.

CbuMeg: ResponseCollection (last edited 2015-01-19 16:09:24 by MaartenVanCasteren)