Suppose we have a three way interaction of three factors called age, sex and type. Each factor has two levels, age and sex are between subject and type is within subject.
Pilot data has suggested an effect size, partial eta-squared, of 0.10 as worthy of interest. We wish to do a power calculation to see how many people we will need to detect an eta-squared of at least 0.10 with a power of 0.80 and a Type I error of 5%.
num = numerator df = (2-1)(2-1)(2-1)=1 d1 = 2-1 = 1 d2 = (2-1) 2-1