RepositioningMRIs - Meg Wiki

You can't save spelling words.

Clear message
location: RepositioningMRIs

Repositioning Structural MRIs

  • This repositioning should provide better normalisation of the of the individual structural MRIs to the Template stuctural, which is in MNI space. If the positioning of the individual MRI is far off the Template MRI, normalisation might fail. You can open and see the template from "/imaging/local/spm/spm5/canonical/single_subj_T1.nii" (below)

template.png

When you open your MRIs you might notice that the orientation might be a bit different than the template:

wiki_struc1.png

First thing to do is to reorient the image to match as close as possible the template. The most common adjustment that needs to be made is the "pitch", as with most images you will need to tilt the head forward, to be fairly similar to the template. Since matlab (and SPM) work with radians and not degrees as units, we enter the value pi/10 = 0.3142, ~18 degrees (1 radian ~57 degrees).

wiki_pi_10.png

Similar, smaller, adjustments are then done for the roll (pi/80, coronal view) and yaw (-pi/80, transverse view)

wiki2.png

Define the anterior commissure as the origin

When opening a structural image in SPM, the origin of the image is not registered to specific anatomical landmark, it is just positioned to the centre of the image. We use the anterior commissure as a landmark for the origin (also is the origin in the Template MRI used by SPM). The anterior commissure is an easily identifiable landmark (see http://imaging.mrc-cbu.cam.ac.uk/imaging/FindingCommissures). To move the crosshairs to the origin, SPM has a not very obvious button, a very narrow rectangle underneath the "Crosshair Position" panel

wiki_origin.png

After the anterior commissure is defined, it's coordinates relative to the existing origin are found in the "Crosshair Position" box, defined in mm, for the x,y,z axes. For the the structural below this corresponds to [0.0 31.3 -11.6].

antcom.png

Since we want to make the anterior commissure the origin, the image needs to be "shifted" by these values. Hence in the "right {mm}" box the value "0" is entered, in the "forward {mm}" the value "-31.3" and in the "up {mm}" box the value "11.6" .

wiki_antcom_newcor.png

Note that the sign of the values entered have the opposite sign than the ones in the Crosshair Position box. This is because the values in the Crosshair Position represent the differences between the current origin and the anterior commissure. Hence, after the anterior commissure is defined, the values entered in the "right", "forward" and "up" boxes should have the opposite sign than the ones in the Crosshair Position box.

Click the "Reorient Images" button and select the file with the structural image which will then be reoriented.

Picture1.png

To make sure that the process has succeeded, open the structural image again and click the the button underneath the "Crosshair Position" to move to the origin. If everything is correct the crosshairs will move to the anterior commissure and the xyz coordinates will be [0.0 0.0 0.0]

checkor.png

Finally, the fiducials can then be marked on the repositioned MRI. The image below shows the marking the nasion on the MRI and its coordinates.

fids.png


CbuMeg: RepositioningMRIs (last edited 2013-03-08 10:02:15 by localhost)